How Accurate Is This Decibel Meter?

Treat an uncalibrated reading as an estimate that can be off by several decibels. Calibrated against a reference meter, a phone can get close for steady, mid-level sound, but it is never a certified instrument.

What the research says

The most careful public tests of phone-based sound measurement come from the U.S. National Institute for Occupational Safety and Health (NIOSH).

Two cautions when applying this to our meter. Those tests covered native iPhone apps, steady noise and a mid-level range. A browser meter has less control over the microphone than a native app, and NIOSH did not consider Android hardware consistent enough to verify. So we do not claim a fixed accuracy figure for an uncalibrated device.

Where the errors come from, and what we do about them

Error sourceWhat happensWhat our meter does
Microphone sensitivityEach device model turns the same sound into a different signal level, so the raw number is shifted up or down.A calibration offset that you set once per device and browser.
Frequency responsePhone and laptop microphones are tuned for speech. They typically lose sensitivity at low bass and very high frequencies.A, C and Z weighting. A-weighting gives less weight to the frequencies where small microphones are weakest, so dBA readings are usually the most trustworthy.
Operating system and browser processingEcho cancellation, noise suppression and automatic gain control are designed for calls. They change the level, sometimes pushing steady noise down over time.We ask the browser to switch all three off, then check what it reports. If processing could not be disabled, the meter shows a notice.
Clipping at high levelsLoud sound overloads the microphone or converter. The signal flattens and the reading stops rising.A clipping badge appears when samples hit full scale. The displayed value is then a lower bound.
Noise floorThe microphone's own electronic hiss sets a minimum reading, so a very quiet room reads higher than it is.Nothing can remove this in software. Treat very low readings as "at or below" the value shown.
Case, hand and positionA case or finger over the microphone port, wind, handling noise and reflections from nearby surfaces all change the result.Hold the device away from your body with the microphone uncovered and pointed toward the source. Use Slow response and Leq for a steadier value.

iPhone and iPad browsers deserve a special mention. Reports in the WebKit bug tracker describe cases where Safari kept processing or filtering the microphone signal even when a page asked it not to. That is why we check the reported settings and tell you, instead of assuming the request worked.

Our own device tests

We are comparing phones and laptops against a reference sound level meter and will publish the results in this table.

DeviceBrowserReference meter readingOur reading (uncalibrated)Difference

Device tests in progress — results will be published here.

What you can rely on

For the exact calculations behind each number, read the methodology. For native apps, see the decibel meter app comparison.

Sources

Frequently asked questions

How accurate is a phone as a decibel meter?

In NIOSH laboratory tests the best iPhone apps averaged within about 2 dB of a reference meter, while others were off by more than 10 dB. Accuracy depends on the phone, the software and whether it has been calibrated.

Why do two phones show different decibel readings?

Microphones differ in sensitivity and frequency response, and phones apply different audio processing. Two uncalibrated devices side by side can easily disagree by several decibels.

Can I use this meter for workplace or legal measurements?

No. Readings are estimates and are not suitable for occupational compliance, legal evidence or medical decisions. Those need a calibrated sound level meter.

What does the clipping badge mean?

The sound was loud enough to overload the microphone or its converter. The true level is at least as high as the reading shown, and probably higher.

How can I make the readings more accurate?

Calibrate against a handheld sound level meter, choose A-weighting when comparing with dBA values, hold the device with the microphone uncovered and avoid wind and handling noise.

Updated

Tools and guides