Noise Exposure Calculator

Enter each sound level in dBA and how long you were exposed to it. The calculator returns the daily noise dose and 8-hour time-weighted average (TWA) under both the NIOSH recommendation (85 dBA, 3 dB exchange rate) and the OSHA rules (90 dBA, 5 dB exchange rate), plus the time you have left at a given level.

Level (dBA)HoursMinutes

NIOSH REL

--

8-h TWA -- dBA

85 dBA · 3 dB · counts ≥ 80 dBA

OSHA PEL

--

8-h TWA -- dBA

90 dBA · 5 dB · counts ≥ 90 dBA

OSHA action level

--

8-h TWA -- dBA

Hearing conservation at 50% (TWA 85 dBA) · counts ≥ 80 dBA

NIOSH -- · OSHA --

Estimates for planning and education only, not a compliance determination. Use a dosimeter or Type 2 sound level meter for workplace assessments.

How to use the calculator

  1. Add one row for each part of the day with a different noise level.
  2. Enter the level in dBA and the duration in hours and minutes.
  3. Read the results: NIOSH dose and TWA, OSHA PEL dose and TWA, OSHA action-level dose, and the time remaining at a level you choose.

The levels should be A-weighted averages for each period. If you do not have measurements, a rough figure from the decibel meter (the Avg/Leq value) or a full-shift log from the noise monitor is enough to explore the numbers.

The formulas

Every method works the same way. For each level L there is an allowed time T. The dose is the sum of the fractions of allowed time you used:

D = 100 × (C1/T1 + C2/T2 + … + Cn/Tn)

where C is the time actually spent at each level. What differs is how T is defined and which levels are counted.

ResultAllowed time T (hours)Levels countedTWA from dose
NIOSH dose8 / 2^((L − 85) / 3)80 dBA and above (NIOSH integrates 80 to 140 dBA)10 × log10(D/100) + 85
OSHA PEL dose8 / 2^((L − 90) / 5)90 dBA and above16.61 × log10(D/100) + 90
OSHA action-level dose8 / 2^((L − 90) / 5)80 dBA and above16.61 × log10(D/100) + 90

The two OSHA doses use the same formula from Appendix A of 29 CFR 1910.95. They differ only in the cut-off. The hearing conservation rules require all sound from 80 to 130 dB to be included, so that dose is compared with the 50% action level. The PEL dose follows Table G-16, which begins at 90 dBA, and is compared with 100%. The constant 16.61 is 5 ÷ log10(2); the NIOSH constant 10 is 3 ÷ log10(2), rounded.

Time remaining at a level is the unused share of the dose multiplied by the allowed time there: (1 − D/100) × T.

Worked example

A worker spends 4 hours at 88 dBA, 2 hours at 95 dBA and 1 hour at 100 dBA. The rest of the shift is below 80 dBA.

PeriodNIOSH TNIOSH C/TOSHA TOSHA C/T
4 h at 88 dBA4 h1.0010.56 h0.38 (action-level dose only)
2 h at 95 dBA0.79 h2.524 h0.50
1 h at 100 dBA0.25 h4.002 h0.50

The same day is "at the limit" by one measure and "seven times over" by another. That gap comes from the exchange rate: NIOSH treats every 3 dB as a doubling of sound energy, which matches the physics of the decibel scale, while OSHA allows 5 dB per halving of time.

Reading the results

Details of each requirement are on our OSHA noise limits page, and safe decibel levels covers exposure outside work.

Sources

Frequently asked questions

How do you calculate noise dose?

Divide the time spent at each sound level by the time allowed at that level, add the fractions and multiply by 100. A dose of 100% means the daily limit has been reached.

How is TWA calculated from noise dose?

Under OSHA, TWA = 16.61 x log10(D/100) + 90. Under NIOSH, TWA = 10 x log10(D/100) + 85. D is the dose in percent.

What noise dose equals the OSHA action level?

A dose of 50%, which corresponds to an 8-hour TWA of 85 dBA. A dose of 100% corresponds to the 90 dBA permissible exposure limit.

Why are the NIOSH and OSHA doses so different?

NIOSH starts at 85 dBA and halves the allowed time every 3 dB. OSHA starts at 90 dBA and halves it every 5 dB. At 100 dBA NIOSH allows 15 minutes and OSHA 2 hours, so the same day gives a much higher NIOSH dose.

Can I use this calculator for OSHA compliance?

No. It shows the arithmetic. A compliance determination needs exposure measurements made with calibrated instruments by a qualified person.