OSHA PEL vs NIOSH REL at a glance
Two numbers govern occupational noise in the United States. The OSHA permissible exposure limit (PEL) is law for general industry under 29 CFR 1910.95. The NIOSH recommended exposure limit (REL) is a health-based recommendation and is not itself enforceable.
| OSHA (29 CFR 1910.95) | NIOSH (Publication 98-126) | |
|---|---|---|
| 8-hour limit | 90 dBA TWA (PEL) | 85 dBA TWA (REL) |
| Exchange rate | 5 dB: time halves for each +5 dB | 3 dB: time halves for each +3 dB |
| Program trigger | Action level: 85 dBA TWA, or a 50% dose | Hearing loss prevention program at or above 85 dBA |
| Upper limit | Impulsive or impact noise should not exceed 140 dB peak | No exposure above 140 dBA |
| Levels counted | 80 to 130 dB for monitoring | 80 to 140 dBA |
| Legal status | Enforceable regulation | Recommendation |
Why the difference matters: NIOSH estimated that over a 40-year working lifetime, the excess risk of developing occupational noise-induced hearing loss is 8% at 85 dBA, compared with 25% at the 90 dBA PEL. For protecting your own hearing, the NIOSH column is the better guide. See safe decibel levels for everyday exposure.
Permissible durations: Table G-16
OSHA's Table G-16 lists the permitted daily duration at each sound level, measured in dBA with slow response. The NIOSH column is calculated from the REL formula for the same levels.
| Sound level (dBA, slow) | OSHA permitted duration per day | NIOSH recommended limit |
|---|---|---|
| 85 | Not in the table (action level) | 8 hours |
| 90 | 8 hours | about 2.5 hours |
| 92 | 6 hours | about 1.6 hours |
| 95 | 4 hours | about 48 minutes |
| 97 | 3 hours | 30 minutes |
| 100 | 2 hours | 15 minutes |
| 102 | 1.5 hours | about 9 minutes |
| 105 | 1 hour | about 5 minutes |
| 110 | 30 minutes | about 1.5 minutes |
| 115 | 15 minutes or less | under 30 seconds |
When the level changes during the day, the standard says the combined effect of the periods must be considered, not each one alone. That is done by adding up fractions of the allowed time into a noise dose, where 100% equals the PEL. Our noise exposure calculator does this for both the OSHA and NIOSH rules.
The 85 dBA action level and the hearing conservation program
Under paragraph (c), an employer must administer "a continuing, effective hearing conservation program" whenever employee exposures equal or exceed an 8-hour TWA of 85 dBA, or equivalently a dose of 50%. Exposure is assessed without counting any reduction from hearing protectors. The program has five main parts.
- Monitoring (d). When information indicates exposure may reach the action level, the employer must develop and carry out a monitoring program. All continuous, intermittent and impulsive sound from 80 to 130 dB is included. Instruments must be calibrated, and monitoring is repeated when a change in production, process, equipment or controls increases exposure. Employees at or above the action level must be told the results.
- Audiometric testing (g). Hearing tests are provided at no cost to employees. A baseline audiogram is required within 6 months of first exposure at or above the action level (within 1 year where mobile test vans are used), preceded by at least 14 hours without workplace noise, and then at least annually. A standard threshold shift is an average change of 10 dB or more at 2,000, 3,000 and 4,000 Hz in either ear; the employee must be informed in writing within 21 days.
- Hearing protectors (i). See the next section.
- Training (k). A training program repeated annually for each employee in the program, covering the effects of noise on hearing, hearing protectors and the purpose of audiometric testing.
- Recordkeeping (m). Noise exposure measurement records are kept for 2 years and audiometric test records for the duration of the employee's employment.
The employer must also make copies of the standard available to affected employees and post a copy in the workplace.
OSHA hearing protection requirements
- Available from 85 dBA. Protectors must be offered at no cost to all employees exposed to an 8-hour TWA of 85 dBA or more.
- Mandatory above the PEL, and from 85 dBA for any employee who is still waiting for a baseline audiogram or who has experienced a standard threshold shift.
- Choice, training and fit. Employees select from a variety of suitable protectors, and the employer must provide training, ensure proper initial fitting and supervise correct use.
- Required attenuation. Protectors must bring exposure down to at least an 8-hour TWA of 90 dBA, or to 85 dBA or below for employees with a standard threshold shift.
Controls come first
Hearing protection is the fallback, not the plan. Paragraph (b)(1) requires that when exposure exceeds Table G-16, feasible administrative or engineering controls be used; only if they fail to bring levels within the table must protective equipment be provided and worn. Engineering controls change the source or the path, such as quieter machines, enclosures and barriers. Administrative controls change who is exposed and for how long, such as rotating tasks or scheduling noisy work when fewer people are nearby. NIOSH ranks controls the same way: removing the noise source is the most effective measure and relying on protective equipment the least.
Construction: 29 CFR 1926.52
Construction work has its own section. Table D-2 in 1926.52 uses the same durations as Table G-16 (90 dBA for 8 hours up to 115 dBA for a quarter hour or less), requires feasible administrative or engineering controls first, and repeats the 140 dB peak statement for impulsive or impact noise. It calls for "a continuing, effective hearing conservation program" where levels exceed the table, but it does not contain the detailed 85 dBA action-level provisions of 1910.95.
A phone meter is not a compliance instrument
If a quick check with the decibel meter shows levels near 85 dBA or more, or people must raise their voice to talk to someone about 3 feet away, ask for a proper noise assessment. To log a full shift for your own reference, use the noise monitor. This page summarizes the regulations and is not legal advice; the regulation text is the authority.
Sources
- 29 CFR 1910.95, Occupational noise exposure (Cornell Legal Information Institute)
- OSHA: 29 CFR 1910.95, official text
- 29 CFR 1926.52, Occupational noise exposure in construction (Cornell Legal Information Institute)
- NIOSH: Criteria for a Recommended Standard, Occupational Noise Exposure, Revised Criteria 1998 (Publication 98-126)
- CDC/NIOSH: Noise-Induced Hearing Loss (REL, exchange rate, hierarchy of controls)
- Canadian Centre for Occupational Health and Safety: Noise, Measurement of Workplace Noise (instrument types)
Frequently asked questions
What is the OSHA decibel limit for 8 hours?
90 dBA as an 8-hour time-weighted average, measured on the A scale with slow response. This is the permissible exposure limit in 29 CFR 1910.95.
At what decibel level does OSHA require hearing protection?
Employers must make hearing protectors available at no cost to every employee exposed at or above an 8-hour average of 85 dBA. Wearing them is mandatory above the 90 dBA permissible limit, and from 85 dBA for employees who have not yet had a baseline audiogram or who have shown a standard threshold shift.
What is the OSHA action level for noise?
An 8-hour time-weighted average of 85 dBA, which equals a dose of 50%. At or above it the employer must have a hearing conservation program.
What is the difference between the OSHA PEL and the NIOSH REL?
The OSHA PEL is a legal limit of 90 dBA over 8 hours with a 5 dB exchange rate. The NIOSH REL is a health-based recommendation of 85 dBA over 8 hours with a 3 dB exchange rate. At 100 dBA OSHA permits 2 hours and NIOSH recommends 15 minutes.
What is the maximum noise level OSHA allows?
Table G-16 ends at 115 dBA for a quarter hour or less, and the standard says exposure to impulsive or impact noise should not exceed 140 dB peak sound pressure level.
Can I use a phone app to check OSHA compliance?
No. A phone or browser meter is a screening tool. Workplace exposure is measured with calibrated sound level meters or noise dosimeters by someone trained to use them.