What offices actually measure
The most thorough recent data set comes from a study published in Applied Acoustics in 2021, which recorded sound at workstations in 43 open-plan offices during normal working hours. Its headline figure is that an A-weighted average (LAeq) of 53.6 dB is typical for an occupied open-plan office. That average changed little with floor size or type of work; the main exceptions were carpeting and ceiling absorption, linked to differences of roughly 3 to 4 dB.
Older reference tables put offices higher. Yale lists a business office at 60 to 65 dBA and Purdue groups "conversation in restaurant, office" at 60 dB.
Why the average is not the problem
At 54 dBA an office is nowhere near a hearing hazard; NIOSH's limit is 85 dBA for 8 hours. The difficulty is that speech is about 55 to 65 dB at 1 meter, so a colleague's phone call is as loud as or louder than everything else in the room and fully intelligible. The same study found that the fluctuation of sound, the gap between the loud moments and the quiet background, was greater in offices with fewer workstations.
What the standards address
ISO 22955:2021, the international standard written for open-plan offices, concentrates on this point. As described in a 2025 conference paper on applying it, the standard gives indicative values for how much speech should be attenuated between zones: from 12 dB between two acoustically active areas, such as an informal meeting zone and a circulation route, up to 32 dB where highly active communication sits next to an area that needs protecting. The paper concludes that the higher values can only be reached with effective screening, not distance alone.
On background level: published design guidance for open-plan offices generally targets a steady background in the mid-40s dBA, with lower values for private offices and meeting rooms. The governing documents (ANSI/ASA S12.2 in the United States, BS 8233 in the United Kingdom) are paid standards that we could not check directly, so confirm the figure in the current edition before using it in a specification.
Reading your own office
- Open the noise monitor at your desk and log a normal hour.
- Note the resting level when nobody nearby is talking. That is your background.
- Note how far the level jumps during nearby conversations. A jump of 10 dB or more is clearly noticeable.
The measurement guide explains averaging, and the pages for 45 dB and 55 dB give reference sounds.
Practical fixes
The measures that follow from the research are absorbent ceilings and carpet, screens between desks, and separating call-heavy teams from focused work. Headphones help individuals, at a moderate volume.
Sources
- Yadav, Cabrera, Kim, Fels & de Dear, "Sound in occupied open-plan offices: Objective metrics with a review of historical perspectives," Applied Acoustics (2021), preprint
- Wassermann, "Practical Application of ISO 22955 for Acoustic Design in Open-Plan Offices," DAGA 2025
- Yale Environmental Health & Safety: Decibel Level Comparison Chart
- Purdue University: Noise Sources and Their Effects
- NIOSH: Noise and Occupational Hearing Loss
Frequently asked questions
What is the average noise level in an open-plan office?
About 54 dBA. A study of 43 occupied open-plan offices reported an LAeq of 53.6 dB as typical.
What is the recommended noise level for an office?
Design guidance generally aims for a steady background in the mid-40s dBA for open-plan areas and lower for private offices. Check the current edition of the applicable standard for exact values.
Is office noise harmful to hearing?
No. Typical office levels are 30 dB below the NIOSH limit of 85 dBA. The effect of office noise is on concentration, mainly from intelligible speech.
Updated