How Loud Is a Generator?

Generator noise is rated at 23 feet (7 m). A small inverter generator is rated at about 48 to 57 dBA depending on load, and a 15 kW home standby unit at about 66 dBA.

Measure your room against 66 dB a generator

Press “Measure now” and allow the microphone to compare your surroundings with this level.

0
Threshold of hearing
30
Whisper
60
Conversation
85
Hearing risk (8 h)
120
Threshold of pain
140
Impulse limit
194
Max undistorted sound
A generator: 48–66 dB

Measured 23 ft (7 m) from the generator.

At this level there is no workplace exposure limit: NIOSH and OSHA limits start at 85 and 90 dBA.

The rating convention: dBA at 23 feet

Generator makers publish sound levels measured 7 meters (23 feet) from the unit. That shared distance is what makes spec sheets comparable, and it is also why the number on the box is lower than what you hear standing next to the machine. Two manufacturer specifications show the typical range:

TypeLoadRated level at 23 ft
2,200 W inverter portablequarter load48 dBA
2,200 W inverter portablerated load57 dBA
15 kW air-cooled home standbynormal load66 dBA

The standby figure is taken from the front of the enclosure; the manufacturer notes that other sides may be louder depending on installation. Open-frame portable generators, which run at a fixed engine speed with no sound enclosure, are generally louder than inverter models of similar output. Their ratings vary widely, so read the spec sheet for the model you are considering.

Portable and standby compared

Estimating the level at your distance

Outdoors, sound falls about 6 dB each time the distance doubles. Starting from 66 dBA at 23 feet:

DistanceEstimated level
6 ftabout 78 dBA
12 ftabout 72 dBA
23 ft66 dBA (rated)
46 ftabout 60 dBA
92 ftabout 54 dBA

Estimates for open ground. A wall behind the unit reflects sound toward the listener and can add several decibels.

Neighbors, campgrounds and hearing

At these levels a generator is a nuisance question, not a hearing hazard: NIOSH's occupational limit is 85 dBA for 8 hours, and the EPA's long-standing guideline for outdoor residential areas is a 55 dB day-night average. A standby unit 23 feet from a neighbor's window exceeds that guideline while it runs, which is why placement matters and why some towns set property-line limits.

Never move a generator indoors, into a garage or close to a window to reduce noise. Engine exhaust contains carbon monoxide.

Measure yours

Pace off 23 feet, open the decibel meter, and compare your reading with the rating. Then measure at the property line and at the nearest bedroom window. For a record of a full run, the noise monitor logs level over time. See 65 dB for context.

Sources

Frequently asked questions

How many decibels is a portable generator?

A small inverter generator is rated at about 48 dBA at quarter load and 57 dBA at rated load, measured at 23 feet. Open-frame models are generally louder.

How loud is a whole-house standby generator?

A 15 kW air-cooled standby unit is rated at about 66 dBA at 23 feet under normal load.

At what distance is generator noise measured?

Manufacturers rate generators at 7 meters, which is 23 feet. Expect a higher level closer in: roughly 6 dB more each time the distance halves.