The rating convention: dBA at 23 feet
Generator makers publish sound levels measured 7 meters (23 feet) from the unit. That shared distance is what makes spec sheets comparable, and it is also why the number on the box is lower than what you hear standing next to the machine. Two manufacturer specifications show the typical range:
| Type | Load | Rated level at 23 ft |
|---|---|---|
| 2,200 W inverter portable | quarter load | 48 dBA |
| 2,200 W inverter portable | rated load | 57 dBA |
| 15 kW air-cooled home standby | normal load | 66 dBA |
The standby figure is taken from the front of the enclosure; the manufacturer notes that other sides may be louder depending on installation. Open-frame portable generators, which run at a fixed engine speed with no sound enclosure, are generally louder than inverter models of similar output. Their ratings vary widely, so read the spec sheet for the model you are considering.
Portable and standby compared
- Inverter portables slow the engine when demand is light, so they are quietest at low load.
- Standby units have larger engines in a sound-attenuating enclosure.
- Load raises the level on every type. A generator running a whole house is louder than one powering a refrigerator.
Estimating the level at your distance
Outdoors, sound falls about 6 dB each time the distance doubles. Starting from 66 dBA at 23 feet:
| Distance | Estimated level |
|---|---|
| 6 ft | about 78 dBA |
| 12 ft | about 72 dBA |
| 23 ft | 66 dBA (rated) |
| 46 ft | about 60 dBA |
| 92 ft | about 54 dBA |
Estimates for open ground. A wall behind the unit reflects sound toward the listener and can add several decibels.
Neighbors, campgrounds and hearing
At these levels a generator is a nuisance question, not a hearing hazard: NIOSH's occupational limit is 85 dBA for 8 hours, and the EPA's long-standing guideline for outdoor residential areas is a 55 dB day-night average. A standby unit 23 feet from a neighbor's window exceeds that guideline while it runs, which is why placement matters and why some towns set property-line limits.
Never move a generator indoors, into a garage or close to a window to reduce noise. Engine exhaust contains carbon monoxide.
Measure yours
Pace off 23 feet, open the decibel meter, and compare your reading with the rating. Then measure at the property line and at the nearest bedroom window. For a record of a full run, the noise monitor logs level over time. See 65 dB for context.
Sources
- Honda Power Equipment: EU2200i specifications
- Generac: 15 kW EcoGen home standby generator specification sheet
- NIOSH: Noise and Occupational Hearing Loss
- EPA: EPA Identifies Noise Levels Affecting Health and Welfare (1974)
Frequently asked questions
How many decibels is a portable generator?
A small inverter generator is rated at about 48 dBA at quarter load and 57 dBA at rated load, measured at 23 feet. Open-frame models are generally louder.
How loud is a whole-house standby generator?
A 15 kW air-cooled standby unit is rated at about 66 dBA at 23 feet under normal load.
At what distance is generator noise measured?
Manufacturers rate generators at 7 meters, which is 23 feet. Expect a higher level closer in: roughly 6 dB more each time the distance halves.
Updated